Auto Transfer Switchboard (ATS)

Product description

*ATS control cabinet in the electrical system is a cabinet connected from the generator, mains, load source, ATS cabinet (Automatic Transfer Switch) is an automatic switching system. In the ATS cabinet there is a system of phase comparison, voltage drop, undervoltage and overvoltage alarm and the load current is also protected such as load loss, overload and generator side equipment as well.

Most engineers build ATS cabinets to let the system automatically when there is a power outage without having to have someone on duty at the transport location to turn on the power when the grid power goes out, depending on the load current, the ATS cabinets are usually calculated from 1 phase, 3 phase or 3 phase 4 poles depending on the common or separate neutral to ensure the load source for the system, reduce the maximum damage to the equipment, the ats devices are calculated according to the current such as ATS 100 A, 200 A, 1000A, 1500 A, 1600 A, 3000 A depending on station and generator capacity. On the control cabinet, there are 02 Auto and Manual devices for the switchboard system, when it is necessary to repair or operate it manually, it is okay and especially the device has an Emegency Stop button, when there is a fire or explosion problem, people will close it. This button to the cabinet back is not controlled. ATS series with brands such as Socomec, Ocemcon BAC, ABB, LS, Schneider, Orom use Contactor for small lines and almost use switching motors for large load current carrying equipment or ACB of brands. famous.

ATS electrical cabinets are used in industrial zones such as factories, industrial workshops, commercial centers, office buildings, apartments, hospitals, ports, airports, etc., where there are loads requiring power supply. continuous, or areas where there is a sudden power outage.

VTStek products are customized according to customer needs.

+ SPECIFICATION
Reference standard IEC 61439-1/2
Form 1, 2a, 2b, 3a, 3b, 4a, 4b
Ingress Protection IP32 to IP54
Ambient temperature -10OC to + 40OC
Rated isolation voltage (Ui) 1000V
Rated operating voltage (Ue) 415/690V
Rated frequency (F) 50/60HZ
Rated current (In) 4000A
Rated short-time current (Icw) 3s 80kA
Earthing diagram TN-S, TN-C
Height (H) 1600/ 1800/ 2000/ 2200
Width (W) 600/ 700/ 800/ 900/1000/1200
Depth (D) 600/ 800/ 1000/ 1200
Color RAL 7035
Electric wiring Top/bottom
Material Electro static power coating/stainless steel
Operating location Indoor/Outdoor

ATS control cabinet in the electrical system is a cabinet connected from the generator, mains, load source, ATS cabinet (Automatic Transfer Switch) is an automatic switching system. In the ATS cabinet there is a system of phase comparison, voltage drop, undervoltage and overvoltage alarm and the load current is also protected such as load loss, overload and generator side equipment as well.